Thermo Keytek ECAT E513
Description
The ECAT E513 by Thermo Fisher Scientific is designed as a voltage ramp generator for testing to a variety of Underwriter Laboratories (UL) standards. This product, does not come with E103 or CDN, which can also be rented for a complete system. This system comes standard with an ISO 17025 accredited calibration and technical support. This system can be controlled via front panel or though the Keytek Software which is provided with the rental upon request.
This Thermo Fisher Scientific / Keytek EMC immunity generator provides single port testing and allows changing tests modes without switching off power to the equipment under test (EUT). This helps testing with the E513 be conducted efficiently without re-initializing the EUT between tests.
This ECAT module is designed to test UL 864, UL 294, and many other EMC standards. The modular system of this Thermo Fisher / Keytek product provides the ability to be upgraded providing the ability to upgrade test capabilities to meet the newest standard. The E103 and E513 combination can be controlled via front panel or through computer using Keytek software.
- Specifications:
- E513 Voltage Ramp Module for ECATS
- Standards
- UL 864,UL 294
- Open Circuit Voltage Ramps
- 0.1kV/us,0.5kV/us,1.0kV/us,5.0kV/us,10kV/us0.1kV/us is linear to 2.5kV;all other ramps are linear to 3.0kV.
- Voltage Durations
- 65us for 0.1kV/us
- 40us for 0.5 kV/us and 1kV/us
- 5us for 5kV/usand 10kV/us
- Current Duration
- 45 us at 0.1kV/us
- 40us at 0.5kV/us and 1.0kV/us
- 4us at 5kV/us and 10kV/us
- Open-Circuit Voltage
- 0-3000V +/-5% in 1 volt steps
- Short-Circuit Current
- 50A +/-10% when the peak open-circuit voltage is set to 3.0kV
- Weight
- 53kg (24lbs)
- Dimensions
- 21 X 52 X 21cm (8� 1/4 X 20 3/8 X 8 1/4)