Teseq CDN 3083-S100 - Rent 100Amp 3-Phase Surge CDN

Availability:
In Stock - Order By 3PM Ships Today!

Teseq 100Amp 3-Phase Surge CDN:

  • Manual Surge Coupler for Teseq NSG 3060/3040 
  • 3-Phase CDN Max 620V/100Amps AC/DC
  • Can be Rented Individually or with Transient System
  • Compliant Coupling to IEC 61000-4-5/ANSI
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Included Items, View Packing List
Got Questions?
Get technical support
Price:
Sale price$22,000
Request A Quote

Related Teseq Test Equipment

Description

Overview

The Teseq CDN 3083-S100 is an external, manual, three phase, 620v, 100a coupler/decoupler for the combination wave/surge and 100kHz ringwave generated by the NSG3060 and NSG 3040. This Teseq Product enables coupling modes with all types of symmetrical and asymmetrical coupling given in the EN/IEC 61000-4-5 and ANSI C62.41 2002.

This coupling decoupling network comes assembled and on wheels, providing an easily maneuverable turnkey solution. An A2LA accredited calibration is included in the price of this test equipment. It is often used in conjunction with the CDN3083-B100 providing 100Amp coupling/decoupling for Burst/EFT (electrical fast transients). These products are ideal for applications that require high AC and DC voltages and currents.

The CDN30830-S100 has all components, surge decoupling networks, INA 3080s, INA 3084 and earth rails installed. This testing accessory also comes with several cables allowing for required connections to be made easily. It can be rented individually to supplement existing testing capabilities, must be used with NSG 3060 or NSG 3040, or in combination with either Teseq surge generator. 

Data Sheet User Manual Application Guide - CDNs

Specifications

Common Standards

EN/IEC 61000-4-5, EN 61000-4-12, CEMark

AC Voltage                

620 V rms (440Vrms with NSG3040)

AC Current

100 A

DC Voltage

620 V rms

DC Current

100 A .


Combination Wave Surge

8 kV /4 kA max.

100kHz Ring Wave

To 6.6 kV

Control

Manual

Connection to generator

Fischer S105 A 004/10.7

Weight

80 kg approx., 176 pounds

Dimensions

85x52x34.5 cm (33.5x20.5x13.6 inches)

All Accessories

Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS. 

Take advantage of A2LA ISO 17025 calibrations and fast deliveries!

 

Full CDN List
Item Capabilities
CDN 3061 Single phase 270 V / 16 A automatic coupling decoupling network
CDN 3063

Three phase 480 V / 32 A automatic coupling decoupling networks

CDN 3083S-100

Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A

CDN 3083B-100 Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A

CDN HSS2

Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet)

CNV504N1.3

4kV coupler/decoupler for Surge & Ringwave on 4 data lines

CDN 3425 

Teseq Burst/EFT couple pulses to data lines.

CM.CCL

Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines 

CDN 3063-C32

Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A

CDN 3063-C63

Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A

CDN 8014/8015

Capacitive coupling clamp for burst

CDN 163

Burst coupling network 100 A per phase (coupling all to ref ground)

CDN 117/118

Coupling networks for signal-/data lines (surge)

CAS 3025

Burst/EFT verification set

MD 200A

Voltage differential probe 7 kV

MD 300

Current probe 5 kA

INA 6501

Manual step transformer, 16 AAC, 0/40/70/80%

INA 6502

Automatic step transformer, 16 AAC, 0/40/70/80%

VAR 3005-S16

Automatic variable transformer, 1 x 16 A

VAR 3005-D16

Automatic variable transformer, 2 x 16 A

MFO 6501

Manual magnetic field option -4-8

MFO 6502

Automatic magnetic field option -4-8

INA 701

Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge* max. 1200 A/m -4-9

INA 702

Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 *) Pulse shape adapter INA 752 needed to surge generator

INA 752

Pulse shape adapter

  

Standards

Widely Used Standards

This list is a more comprehensive list of all the standards covered with this automotive load dump generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.

 

  •  EMC Directives
  • UN ECE R10 (Automotive)
  • IEC/EN 61000-4-5
  • ANSI/IEEE C62.41
  • EN 61000-6-1
  • EN 61000-6-2
  • EN 50370
  • EN 61643
  • EN 300386-2
  • EN 300386 V1.3.2
  • EN 301489-1
  • EN 301489-7
  • EN 301489-17
  • EN 301489-24
  • IEC 60255-1
  • IEC 60601-1-2
  • IEC 61009-1
  • IEC 61326
  • IEC 61850-3