Chroma 61609
Related Equipment
Chroma 61500 Power Supplies
This video shows how to use the Chroma 61500 series of programmable power supplies to conduct a variety of different tests including sags and harmonics tests.
System Overview
Overview
The Chroma 61500/61600 series programmable AC power source are the right solutions to meet complex single and three phase requirements due to their ability to simulate AC line conditions and measure critical product characteristics during testing. These features make the 61500/61600 series ideal for commercial, power electronics, avionics, military, and regulation test applications from bench-top R/D design verification and quality assurance to mass production. DC functionality enhancements, with DC power ratings of up to 75% of full output power, has further extended test application capabilities especially for AC/DC server PSU.
Specifications
Specifications: |
|
Output Phase |
1 or 3 selectable |
Max. Power |
6kVA |
Per Phase |
2kVA |
Voltage |
|
Range: |
0~175V/0~350V/Auto |
Setting Accuracy |
0.1% of RD+0.2% of FS |
Resolution |
0.1 V |
Line Regulation |
0.10% |
Maximum Current (1-Phase Mode) |
|
RMS |
60A/30A |
Peak (CF=4) |
240A/120A |
Maximum Current (each phase in 3-Phase Mode) |
|
RMS |
20A/10A |
Peak (CF=4) |
80A/40A |
Frequency |
|
Range |
15Hz~2000Hz |
DC Output (1-Phase Mode |
|
Power |
6kW |
Voltage |
247.5V/495V |
Current |
60A/30A |
DC Output (3-Phase Mode) |
|
Power |
2kW |
Voltage |
247.5V/495V |
Current |
20A/10A |
Input Rating |
|
Voltage Operating Range *3 |
3Ø 200-240V±10%VLN (WYE) ; 3Ø 200-240V±10%VLL (Delta |
Current |
25A Max./Phase (3Ø 200-240V±10%VLL |
Power Factor |
0.97 (Typical) |
Measurement |
|
Voltage Range |
0~175V/0~350V/Auto |
Voltage Accuracy |
0.1% of RD+0.2% of FS |
Current Accuracy (RMS) |
0.2% of RD+0.2% of FS |
Current Accuracy (peak) |
0.2% of RD+0.4% of FS |
Physical |
|
Dimension (H x W x D) |
221.5 x 425 x 680mm / 8.72 x 16.73 x 26.77inch |
Weight |
50kg / 110 lbs |
- Specifications:
- Output Phase
- 1 or 3 selectable
- Max. Power
- 6kVA
- Per Phase
- 2kVA
- Voltage�
- Range:
- 0~175V/0~350V/Auto
- Setting Accuracy
- 0.1% of RD+0.2% of FS
- Resolution
- 0.1 V
- Line Regulation
- 0.10%
- Maximum Current (1-Phase Mode)
- RMS
- 60A/30A
- Peak (CF=4)
- 240A/120A
- Maximum Current (each phase in 3-Phase Mode)
- RMS
- 20A/10A
- Peak (CF=4)
- 80A/40A
- Frequency
- Range
- 15Hz~2000Hz
- DC Output (1-Phase Mode
- Power
- 6kW
- Voltage
- 247.5V/495V
- Current
- 60A/30A
- DC Output (3-Phase Mode)
- Power
- 2kW
- Voltage
- 247.5V/495V
- Current
- 20A/10A
- Input Rating
- Voltage Operating Range *3
- 3� 200-240V�10%VLN (WYE) ; 3� 200-240V�10%VLL (Delta
- Current
- 25A Max./Phase (3� 200-240V�10%VLL
- Power Factor
- 0.97 (Typical)
- Measurement
- Voltage Range
- 0~175V/0~350V/Auto
- Voltage�Accuracy
- 0.1% of RD+0.2% of FS
- Current Accuracy (RMS)
- 0.2% of RD+0.2% of FS
- Current Accuracy (peak)
- 0.2% of RD+0.4% of FS
- Physical�
- Dimension (H x W x D)
- 221.5 x 425 x 680mm / 8.72 x 16.73 x 26.77inch
- Weight
- 50kg / 110 lbs