Description
Conducted RF CDN Features
- CDN for 3 Conductors Powerline
- Frequency 150 kHz - 300 MHz
- Three-Line (M3) Model - 25Amp Per Line
- Fully Compliant CISPR 16-1-2 and IEC 61000-4-6
- RF Input Voltage: 40 V (Max)
Overview
EMTest automated external transformer for the UCS 500n7 and UCS 500n5 generators to perform the dips and interrupts test for EN IEC 61000-4-11. Voltage dips and short interruptions simulate a reduction of the power supply voltage for a certain period of time. Four different test levels are required as per IEC/EN 61000-4-11. The V 4780 Series of tapped transformer are used to simulate power supply failures such as voltage dips and interruptions providing taps with 40 %, 70 %, 80 % and a direct output with 100 % of the nominal mains supply voltage. Depending on the model the taps are selected manually or by means of the 0-10 V DC signal provided by the test generator.
Data Data SheetSpecifications
Common Standards |
|
Voltage Dips: |
0, 40%, 70%, 80% |
Transition Time |
Risetime, falltime ≥1µs & ≤5µs |
Input Voltage |
250VAC, 50/60Hz |
Input Current |
0 - 16 A rms |
Weight |
7 kg, 15 pounds |
Dimensions |
10x17x19 cm, 4x7x8 inches |