Description
Overview
The CDN 3083-B100 is a manual 100 A three-phase EFT / burst coupling decoupling network (CDN), designed for testing Equipment Under Test (EUTs) up to 690 VAC (L-L or L-PE) and up to 1000 VDC (L-L or L-PE), and used for coupling fast transients (burst pulses) up to 8.8 kV (5 / 50 ns – 50 Ω) into the supply lines of the EUT.
The CDN 3083-B100 is a high quality and affordable solution, ideal for industries and applications that require higher AC and DC voltages and currents, including power & telecom industry, renewable energy applications (smart grid, inverters, solar, energy monitoring devices), electric vehicle and charging stations.
The light weight (5 kg), small size (410 x 170 x 190 mm), and portable design of the CDN takes into consideration the requirements of the latest IEC 61000-4-4 edition 3 standard, including the various test setups, the need for minimum distance between coupling devices and EUTs, and the need to mount coupling decoupling sections directly to the reference ground plane.
Whether you are testing large or small table top equipment, fl oor standing or equipment with elevated cable entries, setting up and handling has never been so fast and easy. The light weight and portability of the CDN 3083-B100 enables you to quick and easily place the CDN at the right position and ensure that minimum distances between CDN and EUT as required by the standard are met. The metal housing construction is such that users can simply place the CDN 3083-B100 directly on the ground reference plane as required by the standard, and guarantees an excellent HF earthing.
High inrush currents or pulse-shaped peak currents can be handled with ease.
In addition, a built-in thermometer enables the heating effect to be monitored. The high quality components used in the design of the CDN enable users to even test for short durations at much higher currents than specifi ed. The current limitation is largely a matter of thermal loading and ambient temperature.
Data Sheet User Manual Application Guide - CDNsSpecifications
Common Standards |
EN/IEC 61000-4-4 |
AC Voltage |
690 VAC RMS |
AC Current |
100A continuous |
DC Voltage |
1000 VDC |
DC Current |
100A continuous |
EFT/Burst 5/50ns |
Max 8.8kv |
Control |
Automatic through the NSG3060 |
Connection to generator |
Fischer S105 A 004/10.7 |
Weight |
5 kg approx., 11 pounds |
Dimensions |
41x17x19 cm, 16x7x7 inches |
All Accessories
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
Full CDN List
Item | Capabilities |
CDN 3061 | Single phase 270 V / 16 A automatic coupling decoupling network |
CDN 3063 |
Three phase 480 V / 32 A automatic coupling decoupling networks |
CDN 3083S-100 |
Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A |
CDN 3083B-100 | Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A |
Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet) |
|
CNV504N1.3 |
4kV coupler/decoupler for Surge & Ringwave on 4 data lines |
CDN 3425 |
Teseq Burst/EFT couple pulses to data lines. |
CM.CCL |
Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines |
CDN 3063-C32 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A |
CDN 3063-C63 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A |
CDN 8014/8015 |
Capacitive coupling clamp for burst |
CDN 163 |
Burst coupling network 100 A per phase (coupling all to ref ground) |
CDN 117/118 |
Coupling networks for signal-/data lines (surge) |
CAS 3025 |
Burst/EFT verification set |
MD 200A |
Voltage differential probe 7 kV |
MD 300 |
Current probe 5 kA |
INA 6501 |
Manual step transformer, 16 AAC, 0/40/70/80% |
INA 6502 |
Automatic step transformer, 16 AAC, 0/40/70/80% |
VAR 3005-S16 |
Automatic variable transformer, 1 x 16 A |
VAR 3005-D16 |
Automatic variable transformer, 2 x 16 A |
MFO 6501 |
Manual magnetic field option -4-8 |
MFO 6502 |
Automatic magnetic field option -4-8 |
INA 701 |
Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge* max. 1200 A/m -4-9 |
INA 702 |
Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 *) Pulse shape adapter INA 752 needed to surge generator |
INA 752 |
Pulse shape adapter |
Standards
Widely Used Standards
This list is a more comprehensive list of all the standards covered with this automotive load dump generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.
- EMC Directives
- UN ECE R10 (Automotive)
- IEC/EN 61000-4-4
- ANSI/IEEE C62.41
- EN 61000-6-1
- EN 61000-6-2
- EN 50370
- EN 61643
- EN 300386-2
- EN 300386 V1.3.2
- EN 301489-1
- EN 301489-7
- EN 301489-17
- EN 301489-24
- IEC 60255-1
- IEC 60601-1-2
- IEC 61009-1
- IEC 61326
- IEC 61850-3