EM Test CA LV 148
Related Equipment
Description
The CA LV 124 set includes four load resistors for the verification of the pulses E10 and E13 of the LV 124 (2013). The load resistors CA LV124-P1R and CA LV124-P100R are used for power line verification. For verification the 16 signal and data lines the CA LV124-D1R and CA LV124-D1000R are used.
As the LV 148 standard requires no data line verification, the CA LV148 consists of a CA LV148-P10R and CA LV148-P1000R for power line verification.
- Specifications:
- NSG 5500
- Instrument power supply:
- 100 to 120 VAC �10%, 47 - 63 Hz
- DUT supply:
- From an external source, e.g. battery or PA 5840 power amplifier / battery
- Computer interface:
- simulator
- Input DC voltage range:
- 60 V max
- DC current:
- 100 A (250 A for 200 ms)
- Voltage drop of battery Switch:
- < 2 V @ 100 A; about 1.5 V @ 25 A
- Battery switch on/off time:
- About 2 us (1 Ohm load)
- Protection class:
- IP20
- LD 5550
- Pulse amplitude:
- 20 to 200 V in 0.1 V steps +/-5%
- Clamping:
- 10 to 100 V +/-5%
Pulse 5b overshoot typ. <2%/2V - Impedance (Ri):
- 0.5 to 10Ohms in 0.25Ohms steps; 30.5Ohms, 40Ohms +/-10%
- Pulse rise time:
- 0.5 to 10 ms +/-10%
<0.5 ms (�10% + 50us)
+/-10% >=50 V pulse amplitude
+/-20% <50V pulse amplitude - Pulse repetition:
- 15 to 600 s in 0.1 s steps, pulse repetition depends on pulse energy
- Pulse modes:
- Single, continuous, programmed 1 to 9,999
- FT 5531
- Pulse Amplitude � 150ns pulse
- 50-800V EUT / 50-600V BNC
- Pulse Amplitude � 100ns pulse
- 50-600V
- Impedance
- 50 ?
- Pulse Rise Time
- 5 ns
- Pulse Width
- 150 ns / 100 ns
- Pulse Frequency
- 1 � 100 Khz
- Burst Interval
- 0.01 to 99.9 ms
- Pulses per burst
- 1 � 200
- Burst Repetition
- 90 ms � 99.9 s in 10 ms steps