Description
Overview
The shielded metal enclosure (SME) is designed to contain two High Voltage Artificial Networks, HV-AN 150 according to ISO/DTS 7637-4 and the HV part of CISPR 12 (draft), CISPR 25, ECE No. 10 R05/06 and ISO 11452-1. It is applicable to all electrical vehicles, i.e., battery, hybrid or plugin electric vehicle. The design of the SME HV-AN 150 allows easy handling when connecting the coaxial HV + and HV lines to the HV-AN.
The cable shield is contacted over a large area through the massive terminals. The inner conductor is strain-relieved by the cable gland and led to the connections of the HV-AN. The SME HV-AN 150 allows the two individual HV AN-150 to be directly connected to the ground plane and allows access to each HV AN. In addition to the box, the scope of delivery of the SME HV-AN 150 includes two RF cables and two connection brackets. The HV-AN 150, the calibration option and the external 10 μF for RTCA/DO-160G must be ordered separately
Data SheetSpecifications
Common Standards |
HV: CISPR 12, CISPR 25, ISO/DTS 7637-4, ISO 11452-1 |
Connectors front panel |
2 x N (female) |
Weight (empty) | 21 kg (approx.) |
Weight (with 2x HV-AN 150) |
31 kg (approx.) |
Dimensions (LxWxH) |
480 x 413 x 225 mm |