AE Techron T1000
Related Equipment
Description
The T1000 Magnetic-Field Susceptibility Transformer was designed to exceed the AF Magnetic Field susceptibility test requirements of DO 160 Section 19 and Boeing D6-16050 Section 7.2. It may also be used as a 10-to-1 step-down transformer for output current of up to 100ARMS.
The T1000 transformer provides up to 300A-m and is able to generate up to 100ARMS. The turns ratio provides a ten-to-one step down to the secondary winding.
The T1000 provides convenient input connectors via binding posts. Standard 0.75-inch spacing of binding posts allows use of standard plugs. Output is via Multi Contact 125A plugs.
A 12-amp circuit breaker protects the unit against over-current conditions. A rugged, impact-resistant case and robust design protects the transformer from accidental damage.
The T1000 transformer is for use by experienced staff.
- Primary:
- 200 VP maximum
- Secondary:
- 20.0 VP maximum output
- Dielectric Test:
- 1200 VDC
- Turns Ratio::
- Ten-to-one step down
- Protection:
- Input power-protected via circuit breaker
- Input Terminals:
- 4-way binding posts
- Output Terminals:
- Multi Contact 125A plugs