Teseq CDN 3063 - Rent NSG 3060 32A/480V 3-Phase CDN

Availability:
In Stock - Order By 3PM Ships Today!

Teseq 3-Phase Surge & EFT CDN:

  • Coupler Decoupling for Teseq NSG 3060/3040 
  • Maximum 3-Phase 480 Volts 32 Amps AC 
  • Can be Rented Individuall or with NSG System
  • Compliant Coupling to IEC 61000-4-4/-5/12
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Included Items, View Packing List

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Related Teseq Transient Equipment

Description

Overview

The Teseq CDN 3063 coupling decoupling network allows for 32Amp 480Volt three phase, EFT, Surge, and 100kHz ringwave for use with the NSG 3040 and NSG 3060. This testing accessory can be rented individually or together as an NSG3060 CDN3063 combination. This accessory is designed for maximum reliability in a wide range of test setups. 

This immunity test equipment includes both IEC and ANSI coupling methods. It also includes a Phase Rotation indicator ensuring correctly sequenced power connection, preventing damage to equipment under test (EUT). An A2LA accredited calibration is included in the EMC test equipment price.

The CDN3063 allows for coupling for testing to EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-12, ANSI C62.41, ANSI C62.45, and UL 1449. Through new technology it offers the ANSI C62.41 coupling method, used to measure and track the mains voltage and simultaneously control the pulse phase angle. We also offer rentals of higher current and voltage networks including the CDN3083-S100 and CDN3083-B100. 

Data SheetUser Manual Application Guide - CDNs

Specifications

Common Standards

EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-12,

ANSI C62.41, ANSI C62.45, & UL 1449

External Three Phase CDN 3063:

Other optional CDN’s  3083 is available also

  AC Voltage             

30-480 VAC, single or 3 phase

  AC Current

32 A  continuous, Max 50A for 10 min.

  DC Voltage

0-125 VDC, 225 VDC if current <7A

  DC Current

32 A  continuous, Max 50A for 10 min


  Control

Automatic through the NSG3060

  Connection to generator

Fischer S105 A 004/10.7

  Weight

42 kilograms, 100 pounds

  Dimensions

45x31x56 cm, 18x12x22 inches

Dips and Interrupts:

INA 6502 external variac is available as a separate option

All Accessories

Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS. 

Take advantage of A2LA ISO 17025 calibrations and fast deliveries!

 

NSG 3060 Full Accessory List
Item Capabilities
CDN 3061 Single phase 270 V / 16 A automatic coupling decoupling network
CDN 3063

Three phase 480 V / 32 A automatic coupling decoupling networks

CDN 3083S-100

Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A

CDN 3083B-100 Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A

CDN HSS2

Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet)

CNV504N1.3

4kV coupler/decoupler for Surge & Ringwave on 4 data lines

CDN 3425 

Teseq Burst/EFT couple pulses to data lines.

CM.CCL

Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines 

CDN 3063-C32

Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A

CDN 3063-C63

Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A

CDN 8014/8015

Capacitive coupling clamp for burst

CDN 163

Burst coupling network 100 A per phase (coupling all to ref ground)

CDN 117/118

Coupling networks for signal-/data lines (surge)

CAS 3025

Burst/EFT verification set

MD 200A

Voltage differential probe 7 kV

MD 300

Current probe 5 kA

INA 6501

Manual step transformer, 16 AAC, 0/40/70/80%

INA 6502

Automatic step transformer, 16 AAC, 0/40/70/80%

VAR 3005-S16

Automatic variable transformer, 1 x 16 A

VAR 3005-D16

Automatic variable transformer, 2 x 16 A

MFO 6501

Manual magnetic field option -4-8

MFO 6502

Automatic magnetic field option -4-8

INA 701

Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge* max. 1200 A/m -4-9

INA 702

Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 *) Pulse shape adapter INA 752 needed to surge generator

INA 752

Pulse shape adapter

  

Standards

Widely Used Standards

This list is a more comprehensive list of all the standards covered with this automotive load dump generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.

  •  EMC Directives
  • UN ECE R10 (Automotive)
  • IEC/EN 61000-4-4
  • IEC/EN 61000-4-5
  • IEC/EN 61000-4-12
  • ANSI/IEEE C62.41
  • EN 61000-6-1
  • EN 61000-6-2
  • EN 50370
  • EN 61643
  • EN 300386-2
  • EN 300386 V1.3.2
  • EN 301489-1
  • EN 301489-7
  • EN 301489-17
  • EN 301489-24
  • IEC 60255-1
  • IEC 61009-1
  • IEC 61326
  • IEC 61850-3

You may also like