Description
Overview
The Teseq NSG 3040 electromagnetic immunity (EMI) test generator provides 4.4kV Surge and 4.4kV electrical fast transient (EFT) with a built-in single phase coupler and is designed primarily for cable-borne transient interference tests. A2LA accredited calibration is included in the EMC rental equipment price. This Teseq products modular architecture and industry standard interfaces allow it to be easily expanded and customized to meet individual testing needs.
This Immunity Test Generator is designed to fulfill conducted EMC testing requirements for CE mark testing, including Combination Wave Surge (4.4 kV), Electrical Fast Transient (EFT) pulses (4.8 kV) and Power Quality Testing (PQT). The NSG3040 includes a 7" color screen and easy to manage user-interface allowing for easy adjustments with the thumb-wheel. This EMC test equipment can also be controlled via PC through the Ethernet Port.
This Teseq (previously known as Schaffner) surge/immunity generator is an all in one box that tests to EN/IEC 61000-4-4, EN/IEC 61000-4-5 and EN/IEC 61000-4-11 and CE Mark with optional INA 6502. Expansion capabilities enable the system to be configured for a much broader range of applications including Telecom Surge 10/700 and Magnetic Field tests. This pulse generator, similar to the NSG 3060, provides the same easy to use interface and connection methods.
Data SheetUser ManualApplication Guide - CDNsSpecifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11, & CE Mark |
Integrated CDN |
|
AC Voltage |
24-260 Vrms, 50/60 Hz (phase-neutral), 400 Hz max |
AC Current |
16 Amps, Max 25 Amps for 15 min. |
DC Voltage |
0-260 VDC, Max |
DC Current |
16 Arms, Max 25Arms for 15 min. |
EFT Burst 5/50ns: |
|
Standards |
IEC 61000-4-4, EN 61000-4-4, CE Mark |
Voltage Waveform into 50Ω load |
5ns Rise Time ±1.5ns, 50µs pulse width ±15ns |
Voltage Waveform into 1000Ω load |
5ns Rise Time ± 1.5ns, 50µs pulse width ± 100/-15ns |
Voltage Amplitude |
± 100V – 2.4kV into 50Ω, ±200V – 4.8kV into 1000Ω |
Burst Duration |
1µ to 1999 s, single pulse and continuous |
Burst Period |
1 ms to 4200 s |
Frequency |
100 Hz to 1000 kHz |
Combination Wave Surge: |
|
Standards |
IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45 |
Open Circuit Voltage Waveform |
1.2µs Front Time ± 30%, 50µs Duration ± 20% |
Short Circuit Current Waveform |
8µ Front Time ± 20%, 20µs Duration ± 20% |
Peak Open Circuit Voltage |
±200V–4.4kV in 1 V step |
Peak Short Circuit Current |
±100A–2.2kA |
Pulse Repetition Rate |
10 s, up to 600 s |
Weight |
25 kilograms, 55 pounds |
Dimensions |
45x22x56 cm, 18x9x22 inches |
Packing List/Accessories
Included with Rental Of Teseq NSG 3040
Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping. We are also excited to offer many different testing accessories not standard with the immunity generator. This does not include any coupler/decoupler items or accessories. A detailed list of these can be found on the "All Accessories" tab.
NSG 3040
- Conducted Immunity System
- Control Software USB with License
- Calibration Documentation
- Power Cord
- Cross Over/ Ethernet Cable
- Printed Manual
- Interlock/Keeper
- Black Plastic Screw
- WIN3000 Installation Guide
- Shipping Case
CDNs
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
Rental Couplers NSG 3040:
Coupler | Capabilities |
CDN 3061 | Single phase 270 V / 16 A automatic coupling decoupling network |
CDN 3063 |
Three phase 480 V / 32 A automatic coupling decoupling networks |
CDN 3083S-100 |
Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A |
CDN 3083B-100 | Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A |
Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet) |
|
CNV504N1.3 |
4kV coupler/decoupler for Surge & Ringwave on 4 data lines |
CDN 3425 |
Teseq Burst/EFT couple pulses to data lines. |
CM.CCL |
Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines |
All Accessories
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
NSG 3040 Full Accessory List
Item | Capabilities |
CDN 3061 | Single phase 270 V / 16 A automatic coupling decoupling network |
CDN 3063 |
Three phase 480 V / 32 A automatic coupling decoupling networks |
CDN 3083S-100 |
Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A |
CDN 3083B-100 | Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A |
Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet) |
|
CNV504N1.3 |
4kV coupler/decoupler for Surge & Ringwave on 4 data lines |
CDN 3425 |
Teseq Burst/EFT couple pulses to data lines. |
CM.CCL |
Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines |
CDN 8014/8015 |
Capacitive coupling clamp for burst |
CDN 163 |
Burst coupling network 100 A per phase (coupling all to ref ground) |
CDN 117/118 |
Coupling networks for signal-/data lines (surge) |
CAS 3025 |
Burst/EFT verifi cation set |
MD 200 |
Voltage differential probe 7 kV |
MD 300 |
Current probe 5 kA |
MD 200A |
Voltage differential probe 7 kV |
MD 300 |
Current probe 5 kA |
INA 165 |
Conducted stand-off |
INA 166 |
Brackets 5 HU for rack mounting |
INA 6501 |
Manual step transformer, 16 AAC, 0/40/70/80% |
INA 6502 |
Automatic step transformer, 16 AAC, 0/40/70/80% |
VAR 6501 |
Automatic variable transformer, 7.5 A |
VAR 6502 |
Automatic variable transformer, 2 x 16 A |
VAR 6503 |
Manual variable transformer, 7.5 A |
MFO 6501 |
Manual magnetic fi eld option -4-8 |
MFO 6502 |
Automatic magnetic fi eld option -4-8 |
Videos
NSG 3060 - Overview & Setup: Transient Specialists
Description: This video provides an overview of the NSG 3060 immunity test generator for surge, ringwave, and electrical fast transient (EFT) testing with the CDN 3061 single phase coupler decoupler 270v/16amps. It talks briefly about capabilities of the test system, setup, and additional considerations. The NSG 3040 has the same design, similar front, and operates in much the same manner.
NSG 3060 -Multifunction Genertor Teseq
Description: This video made by Teseq, now owned by Ametek, provides overview of this test system including the capabilities and changing testing parameter. Video also includes both CDN 3083 & CDN 3061 coupling decoupling networks.