Solar 9354-2
Included Accessories
Can't find something? Contact UsRelated Equipment
Description
The Solar Model 9354-1 and 9354-2 Transient Generators were especially designed for the performance of a variety of pulse susceptibility tests on subsystems and/or equipment, in accordance with MIL-STD-461E/F, Method CS116; also capable of limited testing for RTCA DO-160D, Section 22.
The Model 9354-1 and 9354-2 Transient Generators provide nine selectable waveforms, including six damped sinusoidal pulses (10 kHz, 100 kHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz) and three double exponential pulses (6.4 µS, 70 µS, 500 µS on Model 9354-1. The Model 9354-2 also has three double exponential pulses (6.4 µS, 70 µS, and 120 µS).
Auto pulsing of the sinusoidal repetition rate is internally adjusted from 0.5 to 1.0 pulse per second. A front panel-mounted pushbutton can be used to manually trigger single pulses. The peak amplitude of the selected output pulse is adjustable as a percentage of the charge voltage.The six damped sinusoidal waveforms were designed to meet the requirements of MIL-STD-461E/F, Method CS116. Continuous tunable frequencies can be obtained by the use of the optional variable frequency modules.
The 1 MHz, 10 MHz, and the three double exponential pulses were designed to provide pre-compliance testing of RTCA DO-160D, Section 22. Table 2 lists the test levels that can be achieved from the Models 9354-1 and 9354-2
- Specifications:
- DAMPED SINUSOID PULSES
- 10 kHz
- Open circuit voltage 30 V
Calculated short circuit current 120 A
Source impedance <0.25 Ohms - 100 kHz
- Open circuit voltage 300 V
Calculated short circuit current 120 A
Source impedance <2.5 Ohms - 1 MHz
- Open circuit voltage 3200 V
Source impedance <25 Ohm - 10 MHz
- Open circuit voltage 3200 V
Calculated short circuit current 128 A
Source impedance <25 Ohm - 30 MHz
- Open circuit voltage 1000 V
Calculated short circuit current 20 A
Source impedance <50 - 100 MHz
- Open circuit voltage 300 V
Calculated short circuit current 6 A
Source impedance <50 Ohm - DOUBLE EXPONENTIAL PULSES
- 6.4 uS
- Rise time 100 nS
Open circuit voltage 1600 V
Calculated short circuit current 800 A
Source impedance<2.0 Ohms - 70.0 uS
- Rise time 6.4 uS
Open circuit voltage 1600 V
Calculated short circuit current 800 A
Source impedance <2.0 Ohms - 500 uS (9354-1)
- Rise time 50 uS
Open circuit voltage 1600 V
Calculated short circuit current 400 A
Source impedance <4.0 Ohms - 120 uS (9354-2)
- Rise time 40 uS
Open circuit voltage 750 V
Calculated short circuit current 400 A
Source impedance<4.0 Ohms