EM Test AMP 200N2- Rent LF Signal & Amplifier DC-500KHz

LF Signal & Amplifier System:

  • Output Max. 160 V p-p, 50 V rms, &  18 A rms
  • Low-frequency Source for Ripple Noise & Ground Shifts 
  • Used for DC Magnetic Field Testing with Loop or Coil 
  • Built-in DDS Sinus Signal Generator up to 500 kHz
  • Supports Magnetic Field Tests up to 1100 A/m

Options/Equipment


Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Automotive EMI Generators

Description

Overview

The AMP 200N2 has been designed as a low-frequency signal source to generate sinusoidal signals used to simulate ripple noise and ground shift noise as required by a variety of standards in the avionics, military and automotive industry. The AMP 200N2 is controlled by the NetWave (for testing Electrical Vehicles, avionics, military and nautic standard requirements. e.g LV 123 and ISO 7637-4 Pulse C). The AutoWave is used for automotive testing such as e.g. Ford FMC1278. Additionally, the AMP 200N2 can be used to generate magnetic fields by means of a radiation loop or small Helmholtz coils as per various standards.

Data Sheet User Manual

Specifications

Signal Generator


Frequency range

DC, 10 Hz - 500 kHz (sinusoidal)

Output voltage

+/-10 V, Programmable for control internal or external amplifiers

Amplifier Output


Frequency Range

DC - 500 kHz

Signal power

1,000 W (nominal)

Output voltage

50 Vrms, 160 V(p-p), max. 100 kHz 30 Vrms, 100 kHz - 500 kHz

Output current

Low range:

25 V, Vpmax. 17 V, Vrms max. 18 A, Arms max.


Mid range:

55 V, Vpmax. 37 V, Vrms max. 14 A, Arms max.


High range:

80 V, Vpmax. 55 V, Vrms max. 10 A, Arms max.

DC current

 

25 A, (H-field)

Output Impedance

 

30 mOhm @ 1 kHz

Total Harmonic Distortion (THD)

< 0.1 % Load (< 4 ohm, < 100 kHz)

Protection

- Short circuit

- Overtemperature

Dimensions

19", 6 HU (500 mm x 449 mm x 286 mm)

Weight

Approx. 40 kg

Supply voltage

115 V +10/-02 %, 50/60 Hz or 230 V +10/-15 %, 50/60 Hz

Input power

Max. 1,900 VA

Standards

Widely Used Standards

  • ISO 7637-4 
  • ISO 11452-8
  • VW 80300 
  • BMW GS 95002 
  • Chrylser CS-11979 
  • Fiat 9.90110 
  • Ford EMC-CS-2009.1 
  • GMW 3097 
  • GMW 3172 
  • MAN 3285 
  • Mazda MES PW 67602 
  • Mercedes MBN 10284-2 
  • Nissan 28401 NDS 02 PSA B21 7110 
  • Renault 36-00.808/--N 
  • Volvo STD 515-003 
  • VW TL 801 01 
  • Ford FMC 1278 
  • Jaguar JLR-EMC-CS 
  • Hyundai Kia ES 96200-00 
  • Mitsubishi ES-X82115 
  • Tesla TS-0000048-06 FCA CS.00054 Case
  • New Holland ENS0310 
  • Mercedes MBN 10284-4 
  • Tesla TS-0000425-05