EM Test VDS 200Q50.2 - Front Side
EM Test VDS 200Q50.2 - Front
EM Test VDS 200Q50.2 - Back
EM Test VDS 200Q50.2 - Front Top

EM Test VDS 200Q50.2

Rent 50 Amp Battery Simulator
  • -60 to +60 Volts 50 Amps Continuous
  • Pulses 4 and 2b (ISO 7637-2/ISO 16750-2)
  • Extended Range 80 Volts 40 Amps
  • iso.control Software Included
  • Current ISO 17025 Accredited Calibration

Included Accessories

  • Battery Simulator/Generator  
  • Power Cable
  • USB Interface Cable
  • Printed Manual
  • Calibration Documentation 
  • Short Introduction
  • USB Drive with License & Software
  • 125V Plug
  • (2) MC Connector Cable (red & black)
  • (2) Clamps Red & Black
  • Red Shipping Case
Can't find something? Contact Us
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

The VDS 200Q series is used to simulate the various battery supply waveforms  recommended by international standards and by car manufacturer requirements. Especially the manufacturer requirements are an important area covered by the VDS 200Q series as there is a large variety of requirements. Secondly, the VDS 200Q series serve as powerful DC voltage supplies for the DUT during the tests with automotive transients. The VDS 200Q series covers all three supply voltage categories (48 V, 24 V and 12 V). Their current capability ranges up to 100 A or more depending on the model and your application.

Specifications:
Output Voltage
- 20 Volts to +80 Volts
Output Current
0A to 50A, continuous
Peak Current
150 A for 200 ms
Frequency Range
DC to 150 kHz full signal
Supply Voltage
3-phase 200/500V +/- 10% (L1, L2, L3, PE)
Weight
275 kg
Dimensions
19"/25 HU*)
COMMON DATA (ALL MODELS)
Operation�
4- quadrant, Bipolar operation
Source impedance
Zi = Programmable <10mohm, 10-200mOhm selectable
Current limiter
3x Imax: allows an inrush current of three times nominal current for 200 ms before the current limiter starts 3x ictrl: allows an inrush current of three times the programmed current for 200 ms before the current limiter starts Peak OFF: no inrush current above the set current value (not available for VDS 200Q10)
�Compensation
STD: DC - 40 kHz
HF: DC - >=150 kHz
CAP: DC - 3kHz
Output rise time
UR <10 mVp-p, frequency min. 400 Hz
Control�
Analog In
TRIGGER
Automatic
Automatic release of the events
Manual
Manual release of a single pulse
External
External release of a single pulse
OUTPUT
DUT Supply +/-
Safety laboratory or high current connectors
Ext. trigger
5-15V TTL; BNC connector
CRO Trigger
5V TTL-signal for oscilloscope
TEST ROUTINES FOR ARBITRARY WAVES
DC source
Max. 60V; current depending on VDS 200N model
Functions
Sine Wave Sweep
Sine Wave (Cranking)
Clipped Load Dump
Jump Start
Extern
GM 9105P Pulse 4
Drop and Jump pulse
Standard Test routines
ISO 7637, Pulses 2b and 4 ISO 16750-2 Jaso Test 1
Service
Service, Setup, Self test
INTERFACE
Serial interfaxe
USB
Parallel interface
IEEE 488, addresses 1 - 30
Remote control
To connect an external signal generator (10kohm): 0-10V / 0-50kHz max. 0.5V(p-p) / 0-100kHz
Video Guides
LV124 Testing with the EM Test VDS 200Q100.2 & Autowave
EM Test VDS 200Q10 ISO 7637-2 Testing
Related Videos
EM Test AutoWave Waveform Generator Walkthrough
OEM LV 124 Testing PA 5840, AutoWave, & PFM 200N