EM Test VDS 200Q50.2
Included Accessories
Can't find something? Contact UsRelated Equipment
Description
The VDS 200Q series is used to simulate the various battery supply waveforms recommended by international standards and by car manufacturer requirements. Especially the manufacturer requirements are an important area covered by the VDS 200Q series as there is a large variety of requirements. Secondly, the VDS 200Q series serve as powerful DC voltage supplies for the DUT during the tests with automotive transients. The VDS 200Q series covers all three supply voltage categories (48 V, 24 V and 12 V). Their current capability ranges up to 100 A or more depending on the model and your application.
- Specifications:
- Output Voltage
- - 20 Volts to +80 Volts
- Output Current
- 0A to 50A, continuous
- Peak Current
- 150 A for 200 ms
- Frequency Range
- DC to 150 kHz full signal
- Supply Voltage
- 3-phase 200/500V +/- 10% (L1, L2, L3, PE)
- Weight
- 275 kg
- Dimensions
- 19"/25 HU*)
- COMMON DATA (ALL MODELS)
- Operation�
- 4- quadrant, Bipolar operation
- Source impedance
- Zi = Programmable <10mohm, 10-200mOhm selectable
- Current limiter
- 3x Imax: allows an inrush current of three times nominal current for 200 ms before the current limiter starts 3x ictrl: allows an inrush current of three times the programmed current for 200 ms before the current limiter starts Peak OFF: no inrush current above the set current value (not available for VDS 200Q10)
- �Compensation
- STD: DC - 40 kHz
- HF: DC - >=150 kHz
- CAP: DC - 3kHz
- Output rise time
- UR <10 mVp-p, frequency min. 400 Hz
- Control�
- Analog In
- TRIGGER
- Automatic
- Automatic release of the events
- Manual
- Manual release of a single pulse
- External
- External release of a single pulse
- OUTPUT
- DUT Supply +/-
- Safety laboratory or high current connectors
- Ext. trigger
- 5-15V TTL; BNC connector
- CRO Trigger
- 5V TTL-signal for oscilloscope
- TEST ROUTINES FOR ARBITRARY WAVES
- DC source
- Max. 60V; current depending on VDS 200N model
- Functions
- Sine Wave Sweep
- Sine Wave (Cranking)
- Clipped Load Dump
- Jump Start
- Extern
- GM 9105P Pulse 4
- Drop and Jump pulse
- Standard Test routines
- ISO 7637, Pulses 2b and 4 ISO 16750-2 Jaso Test 1
- Service
- Service, Setup, Self test
- INTERFACE
- Serial interfaxe
- USB
- Parallel interface
- IEEE 488, addresses 1 - 30
- Remote control
- To connect an external signal generator (10kohm): 0-10V / 0-50kHz max. 0.5V(p-p) / 0-100kHz