ECAT E103, E506-4W, E508, E509 - Belcore 1089 Telecom EMC Immunity Test System

RENTAL

ECAT E103, E506-4W, E508, E509 - Belcore 1089 Telecom EMC Immunity Test System

ECAT system for Telecordia Lightning Surge for GR-1089-CORE, Includes the E506-4W (2x10) waveform the E508 (10x360) waveform and the E509 (10x1000) waveform



ECAT system for Telecordia Lightning Surge for GR-1089-CORE, Includes the E506-4W (2x10) waveform the E508 (10x360) waveform and the E509 (10x1000) waveform

 

Controller-E103

Controller for the ECAT system with front panel and software operation.

Telecom Surge 2x10-E506-4W

 

Standards

GR 1089-Core

Waveforms

<2/>10µs,50-800V  100A/terminal with 800V OCV   

<2/>10µ,50-1500V  100A/terminal with 1500V OCV     

<2/>10µs, 100-2500V, 500A/terminal with 2500V OCV

<2/>10µs,200-5000V,  100A/terminal with 5000V OCV          

Peak Open Circuit Voltage

-0%/+20%

Peak Short Circuit Current

-0%/+20%

Pulse Repetition Rate

1 Shot/16 seconds

Weight

44kg, 97lb

Dimensions

21x42x52 cm , 8x16x20 inches

Telecom Surge Module – E508

 

Standards

GR 1089-CORE

Open Circuit Voltage Waveform

10/360µs

Short Circuit Current Waveform

10/360µs

Peak Open Circuit Voltage

50-1100V,-0±15% in 1 voltage steps

Peak Short Circuit Current

100A/side

Pulse Repetition Rate

1 shot/50 seconds

Weight

11kg,25 lb

Dimensions

21x42x52cm, 8x16x20 inches

E509 Telecordia Lightening Surge

 

Standards

GR 1089-CORE

Open Circuit Voltage Waveform

10/1000µs, 50-600V -0/+15% peak

10/1000µs,50-1000V -0/+15%peak

10/1000µs,50-1500V -0/+15%peak

Short Circuit Current Waveform

100A/side -0/+15%peak

Duration

-0/+50% for Voltage

Front Time

-30%/+0 for Voltage

Pulse Repetition Rate

1 shot/40 seconds

Weight

16kg, 35 pounds

Dimensions

21x42x52 cm, 8x16x20 inches