Description
Overview
The Teseq CDN HSS-2 Coupling Decoupling Network is designed for convenient surge testing with 1.2/50 μs pulses, as defined in EN/IEC 61000-4-5, on unshielded symmetrical high speed telecommunication lines e.g. Ethernet. A2LA accredited calibration is included in the EMC rental equipment price. This product allows testing on ISDN and Ethernet with 10/100BaseT and 1000BaseT. With a surge test voltage of 2 kV is the maximal residual voltage at the AE port only 65 V due to the excellent decoupling network. Additional decoupling elements are not required to protect the auxiliary equipment (AE).
Data Sheet User ManualSpecifications
Common Standards |
EN/IEC 61000-4-5 |
Max. surge test voltage |
2 kV (1.2/50 µs pulse per EN IEC 61000-4-5) |
Max. surge test current |
50 A (8/20 µs pulse per EN IEC 61000-4-5) |
Cable type |
8 wire unshielded twisted pair high speed telecom lines (UTP) |
Application |
ISDN, 10/100 Base T, 1000 Base T |
Insertion Loss |
9dB at 100MHz |
Max. Operating Speed |
1000 Base T |
Max. Operating Voltage |
100 VDC between pairs |
Max. Operating Current |
1 A |
Connection to generator |
Fischer D103 A 023 |
Connection to EUT or AE |
RJ45 female |
Weight |
15 kilograms, 33 pounds |
Dimensions |
20x20x47 cm, 8x8x18 inches |