Description
Overview
The newest Teseq (Ametek) NSG 3060A Immunity generator provides testing a test solution for a variety of different transient requirements including surges and electrical fast transients. A2LA accredited calibration and two free days of transit time is included in the rental equipment price. It includes both coupling methods associated with IEC and ANSI testing standards. We also offer a variety of accessories available for rent, including the PCD 8 s-3-690-1000-200 series (up to 200amps Supply Lines)
The NSG 3060A has an Ethernet port for external PC control. The Windows-based control software simplifyes test programming and allows compilation of complex test sequences with diverse pulse types. Test reports can be generated during the test operation, allowing the operator to enter observations as the test progresses and increasing the efficiency of long-term tests.
The Teseq generator has an Ethernet port for external PC control. The Windows-based control software simplifies test programming and allows compilation of complex test sequences with diverse pulse types. Test reports can be generated during the test operation, allowing the operator to enter observations as the test progresses and increasing the efficiency of long-term tests.
Data SheetUser ManualSpecifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, ANSI C62.41, C62.45, UL 1449 |
Electrical Fast Transients (EFT/Burst) |
IEC 61000-4-4 |
Pulse amplitude: |
±200 V to 4.8 kV (in 1 V steps) - open circuit ±100 V to 2.4 kV (50 Ω matching system) |
Burst frequency: |
100 Hz to 1000 kHz |
Polarity: |
positive / negative / alternate |
Repetition time: |
10 ms to 9'999 ms |
Burst time: |
0.01 ms to 9'999 ms, single pulse |
Test duration: |
1 s to 9’999s, 1 min to 1600 min, endless |
Phase synchronization: |
asynchronous, synchronous 0 to 359º (in 1º steps) |
Combination Wave Surge: |
|
Pulse voltage (open circuit): |
±200 V to 6.6 kV (in 1 V steps) |
Pulse current (short circuit): |
±100 A to 3.3 kA |
Impedance: |
2/12 Ω |
Polarity: |
positive / negative / alternate |
Pulse repetition: |
10 s* up to 9’999 s (in 1 s steps) |
Test duration: |
1 to 99’999 pulses, continuous |
Phase synchronization: |
asynchronous, synchronous 0 to 359º (in 1º steps) |
Coupling: |
ANSI / IEC / external |
* Repetition rate depends on voltage: |
200 to 4400 V = 10 s repetition time 4401 to 6600 V = 20 s repetition time |
All Accessories
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
NSG 3060A Options & Accessories List
Item | Capabilities |
CDN 3063A-C32 | Three phase 480 V / 32 A automatic coupling decoupling networks for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV |
CDN 3063A-C63 |
Three phase 480 V / 63 A automatic coupling decoupling network for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV |
CDN 3063A-C100 |
Three phase 480 V / 100 A automatic coupling decoupling network for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV |
CDN 3425 | Burst EFT capacitive coupling clamp for data line coupling per IEC 61000-4-4 |
CDN 117A-C6-4-1 |
Coupling networks for unsymmetrical signal-/data lines (surge) |
CDN 118A-C6-4-1 |
Coupling networks for symmetrical signal-/data lines (surge) |
CDN HSS-2 |
Teseq Burst/EFT couple pulses to data lines. |
PVF BKIT 1 |
Burst/EFT verification set |
MD 210 |
Voltage differential probe 7 kV common / differential 1000:1 / 100:1 |
MD 300 |
Current probe 5 kA |
Accessories for IEC/EN 61000-4-11 |
|
TVT 1-250-16 |
Manual step transformer, 16 AAC, 0/40/70/80% |
VAR 3005A-S16 |
Automatic single variable transformer, 1 x 16 A |
Accessories for IEC/EN 61000-4-8/-4-9 |
|
MFO 6501A |
Manual magnetic field option -4-8 |
MFC 30 |
Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 |
MFC 300 |
Magnetic field coil 1 x 1 m; max. 330 A/m -4-8 |
Standards
Widely Used Standards
This list is a more comprehensive list of all the standards covered with this immunity generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.
- EMC Directives
- UN ECE R10 (Automotive)
- IEC/EN 61000-4-4
- IEC/EN 61000-4-5
- IEC/EN 61000-4-8
- IEC/EN 61000-4-9
- IEC/EN 61000-4-11
- IEC/EN 61000-4-12
- IEC/EN 61000-4-29
- ANSI/IEEE C62.41
- EN 61000-6-1
- EN 61000-6-2
- EN 50370
- EN 61643
- EN 300386-2
- EN 300386 V1.3.2
- EN 301489-1
- EN 301489-7
- EN 301489-17
- EN 301489-24
- FCC 97-270 (part 68)
- IEC 60255-1
- IEC 60601-1-2
- IEC 61009-1
- IEC 61326
- IEC 61850-3
- ITU-T K.12
- ITU-T K.20
- ITU-T K.21
- ITU-T K.28
- ITU-T K.41
- ITU-T K.44
- ITU-T K.45
Videos
NSG 3060 - Overview & Setup: Transient Specialists
Description: This video provides an overview of the NSG 3060 immunity test generator for surge, ringwave, and electrical fast transient (EFT) testing with the CDN 3061 single phase coupler decoupler 270v/16amps. It talks briefly about capabilities of the test system, setup, and additional considerations. All of these pieces of test equipment are available for rental and come with ISO 17025 calibrations.
NSG 3060 -Multifunction Genertor Teseq
Description: This video made by Teseq, now owned by Ametek, provides overview of this test system including the capabilities and changing testing parameter. Video also includes both CDN 3083 & CDN 3061 coupling decoupling networks.