Haefely AXOS 8 Front Side
Haefely AXOS 8 Front
Haefely AXOS 8 Video Guide Surge Testing
Haefely AXOS 8 Back
Haefely AXOS 8 Front Side Above

Haefely AXOS 8

Rent 7 kV Transient Test Generator
  • 7 kV Surge, 5.5 kV EFT, & 7 kV 100 kHz Ringwave
  • Built-in CDN Max 264 V/16 A AC or 220 V/10 A DC
  • Compliant to ANSI Coupling Requirements 
  • Easy to Operate with Automated Test Modes
  • Current ISO 17025 Accredited Calibration

Included Accessories

  • Generator s/n
  • Printed User Manual
  • Calibration Documentation
  • Power Cord
  • EUT IN Power Cord with MC Connectors
  • EUT OUT Power Cord with MC Connectors
  • SHV to SHV Cord
  • BNC to BNC Cord
  • (4) MC Connectors
  • (4) 25cm Purple, Black, Blue, Yellow Patch Cords with MC Connectors 
  • Wing Nut (attached to ground terminal)
  • Red Wire Jumper (4-5) Aux 
  • Ethernet Cable
  • USB Cable
  • Shipping Case
Can't find something? Contact Us
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

Welcome to the unique design and concept of modularity designed by HAEFELY.

HAEFELY is recognizing an increasing interest in testing departments to configure the required functions in compact immunity test systems more flexible than ever. For that reason HAEFELY designed a unique concept of modularity which eviscerates large additional investments for customers in the future.

Moreover, constantly reduced product development times call for powerful, easy-to- operate and ready-touse conducted immunity test systems which can be expanded in a multitude of different test applications. Customer requirements, particularly in the telecommunications and industrial electronics sector, emphasize a test system‘s accuracy and modularity, thus clearly pointing to easy to expand T&M equipment that is favourably priced and suitable for most of industries.

The new AXOS series has been tailored to exactly meet these requirements, offering special cost advantages for T&M applications in the development, production and servicing of telecommunications, components as well as safety and industrial electronics.

All AXOS test systems come equipped with all the hardware needed for instant upgrades by only entering optional key codes into the licence code manager of the unit. After entering the key code(s) the additional test functionalities like Surge Combination Wave, Ring Wave, Telecom Wave, EFT/Burst or Voltage Dips and Interrupts become available immediately. No direct intervention has to be done by the user at all. 

Specifications
IEC / EN 61000-4-4 Edition 2 & 3 EFT:
Output Voltage
0.2 to 5.0 kV +/-10% at coaxial output
Rise Time
5 ns +/-30%
Impulse duration
50 ns +/-30% at 50 Ohm
50 ns - 15 +100 ns at 1000 Ohm
Burst Mode
normal, continuous, real, random
IEC / EN 61000-4-5 Edition 2 & Edition 3 Surge:
Output Voltage
0.2 - 7.0 kV +/-10%
Voltage Rise Time / Impulse duration
1.2 us +/-30% / 50 us +/-20%
Output Current
0.1 - 3.5 kA +/-10%
Current Rise Time / Impulse Duration
8 us +/-20% / 20 us +/-20%
IEC / EN 61000-4-5 Telecom Wave:
Output voltage
0.2 to 7.0 kV +/- 10%
Front time OCV / Decay Time OCV
10 us +/- 30% / 700 us +/- 20%
Front time SCC
5 ?s +/- 20%
IEC / EN 61000-4-11 & IEC / EN 61000-4-29
Max. voltage
264 V AC/DC
Max. current
16 A AC/DC continuous 20 A for 5 s , 23 A for 3 s , 40 A for 3 s, > 500 A inrush current
IEC / EN 61000-4-12
Max. voltage
0.2 - 7.0 kV +/- 10%
Frequency
100 kHz
Rise time OC / Rise time SC
5 ?s / 1 ?s
AXOS5 Options and Accessories:
FP-EFT 32M
3-Phase CDN EFT/Burst 32 A / 690 V
FP-EFT 100M2
3-Phase CDN EFT/Burst 100 A / 690 V
IP4A
Capacitive Coupling Clamp for EFT/Burst
FP-SURGE 32A
Automatic 3-Phase CDN Surge 32 A / 690 V
FP-SURGE 100M2
3-Phase CDN Surge 100A / 690 V
PCD 121
Symmetrical Data & Control Line Coupler
PCD 126A
Asymmetrical Data & Control Line Coupler
5-Dec
Symmetrical Data & Control Line Decoupler
6-Dec
Symmetrical Data & Control Line Decoupler
7-Dec
Asymmetrical Data & Control Line Decoupler
DIP 116
Automatic Dips Transformer 16 A 40/70/80%
MSURGE-A
Magnetic Field Test IEC / EN 61000-4-9
VTM 15000
Isolation Test 1.2/50 us up to 10 kV
VTM 15000/05
Isolation Test 1.2/50 us up to 10 kV / 0.5J
PDP 8000 HV
Differential Probe 1000:1 for Surge
CP 101
Current Probe Model for Surge
ES
External Emergency Stop Switch P12
WL
External Warning Lamp P12
TW 8
Telecom Wave Modul 10/700?s
Calibration
Accredited Calibration AXOS according to ISO/IEC 17025
Key Codes:
Surge Key Code
Key Code for Surge extension AXOS
EFT/Burst Key Code
Key Code for EFT/Burst extension AXOS
Ring Wave Key code
Key Code for Ring Wave extension AXOS
Dips Key Code
Key Code for Voltage Dips extension AXOS
Remote Control and software:
Remote Control
Remote Control Software for AXOS
Report Software
Reporting Software for AXOS
Related Videos
Haefely AXOS Generator Overview
Haefely DIP 116 Overview & Conducting Testing