EM Test Variac NX 1-260-16 - Rent Single Phase Motor Variac

EM Test Variable Transformer:

  • Single Phase Motor Variac 50 Hz to 60 Hz
  • Compliant Solution for IEC 61000-4-11 Testing
  • Used with EM Test NX5 and NX7 Test Systems
  • Allows for Testing up to 1,000 Amps with MFT 100
  • Maximum 280 Volts 16 Amps Continuous

Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Related Test Equipment

Description

Overview

The single phase motor variacs of the NX 1-260-XX series allow to steplessly adjust the EUT supply voltage from 0V to 260 V (280 V) when supplied by a 230 V mains supply voltage. By means of the variac NX 1-260-xx series tests as required in the standard IEC / EN 61000-4-11 (voltage dips and short interruptions as well as the optional voltage variation) can be performed adjusting the voltage to any voltage level. Apart from this the motor variac is used for power-frequency magnetic field tests as per IEC / EN 61000-4-8.

Data Sheet User Manual

Specifications

Input Voltage  Max 250 V

Frequency

50 Hz/60 Hz

Output voltage

0 - 130 V @115 V,

0 - 260 V @230 V,

0 - 275 V @250 V

Output current

Max. 16 A (variac NX1-260-16)

Output power

0 to 4,160 VA

Technical Data


Output PF1

Nominal mains supply voltage

Output PF2

0 V - maximum output voltage (depending on the model and supplied mains supply voltage)

Output connectors

4 mm safety lab connectors PF1, PF2, Neutral and PE

Dimensions

19" / 6 HU 266 mm x 485 mm x 400 mm (HxLxW)

Weight

approx. 27 kg

Supply voltage

115/230 V

Fuses

20 A (PF1), 16 A (PF2)