Description
Overview
The EM Test VDS200Q series of automotive batter supply/voltage drop simulator provides testing capabilities for a variety of standards including ISO 7637. This series provides provides a diverse set waveforms recommended by both international and manufacturer standards. We offer rentals of both the 15amp (VDS 200N15) and 30amp (VDS 200N30) test solutions which can be used independently or integrated into an EM Test 200 series automotive immunity setup. This piece of test equipment comes with an ISO 17025 accredited calibration and a laptop with software installed, providing a quick solution.
Data Sheet User Manual
Specifications
Common Standards |
ISO 7637-2 pulses 2b and 4, ISO 16750, GMW3172 and many others |
Output Voltage |
- 20 Volts to +80 Volts |
Output Current |
0A – 50A, continuous |
Peak Current |
150 A for 200 ms |
Frequency Range |
DC to 150 kHz full signal |
Supply Voltage |
3-phase 200/500V +/- 10% (L1, L2, L3, PE) |
Weight |
275 kg |
Dimensions |
19"/25 HU*) |
COMMON DATA (ALL MODELS) |
|
Operation |
4- quadrant, Bipolar operation |
Source impedance |
Zi = Programmable <10mohm, 10-200mOhm selectable |
Current limiter |
3x Imax: allows an inrush current of three times nominal current for 200 ms before the current limiter starts 3x ictrl: allows an inrush current of three times the programmed current for 200 ms before the current limiter starts Peak OFF: no inrush current above the set current value (not available for VDS 200Q10) |
Compensation |
STD: DC - 40 kHz HF: DC - >=150 kHz CAP: DC - 3kHz |
Output rise time |
UR <10 mVp-p, frequency min. 400 Hz |
Control |
Analog In |
TRIGGER |
|
Automatic |
Automatic release of the events |
Manual |
Manual release of a single pulse |
External |
External release of a single pulse |
OUTPUT |
|
DUT Supply +/- |
Safety laboratory or high current connectors |
Ext. trigger |
5-15V TTL; BNC connector |
CRO Trigger |
5V TTL-signal for oscilloscope |
TEST ROUTINES FOR ARBITRARY WAVES |
|
DC source |
Max. 60V; current depending on VDS 200N model |
Functions |
Sine Wave Sweep Sine Wave (Cranking) Clipped Load Dump Jump Start Extern GM 9105P Pulse 4 Drop and Jump pulse |
Standard Test routines |
ISO 7637, Pulses 2b and 4 ISO 16750-2 Jaso Test 1 |
Service |
Service, Setup, Self test |
INTERFACE |
|
Serial interfaxe |
USB |
Parallel interface |
IEEE 488, addresses 1 - 30 |
Remote control |
To connect an external signal generator (10kohm): 0-10V / 0-50kHz max. 0.5V(p-p) / 0-100kHz |
VDS 200Q Series
VDS 200Q Series |
|
VDS 200Q10 |
Voltage Drop Simulator, 60V/10A |
VSD 200Q25.2 | Voltage Drop Simulator, 80V/25A |
VDS 200Q50.2 |
Voltage Drop Simulator, 80V/50A |
VDS 200Q100.2 |
Voltage Drop Simulator, 80V/100A |
VDS 200Q150.2 |
Voltage Drop Simulator, 80V/150A |
VDS 200Q200.2 |
Voltage Drop Simulator, 80V/200A |
Video
EM Test - Automotive Conducted Immunity Generators
Description: This video provides an overview on the EM Test conducted immunity test system. The three major components of this automotive EMC test equipment are the LD 200N, UCS 200N, and VDS 200N. This video provides and overview of these test systems including, ISO 7637-2 waveforms covered, accessories that come with equipment, setup, connecting all equipment, and troubleshooting. It also, provides insight into how to setup the software to allow remote testing to be conducted through laptop.
Standards
Widely Used Standards
- Audi (Reference vehicles)
- BMW - (Airbag ECU)
- BMW 600 13.0 (Part 1)
- BMW 600 13.0 (Part 2)
- BMW GS 95002 (2010)
- BMW GS 95003-2
- BMW GS 95024-2-1
- ISO 21848:2005
- ISO 14982
- ISO 16750-2
- ISO 7637-2:2004
- ISO 7637-2:2011
- LV 124
- LV 148
- MBN LV 124-1
- SAE J1113-11
- SAE J1113-11 (rev.2000)
- SAE J1113-11 (rev.2007)
- VW 80000