CA BS 200N

Load Impedance for BS 200N

  • 0.6ohm / 50uH Load as per ISO 7637-2:2004
  • Max Supply Voltage 28VDC
  • Max Load Current 50A
  • Built-in 10, 20, 40, & 120 Ohm Resistors
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Overview

CA BS 200N - Load Impedance for BS200Nx Electronic Switches The switching behaviour of the BS 200N series semiconductor switches shall be verified on 0.6ohm to 50uH load inpedance. The CA BS 200N is directly connected to the output of the BS 200Nx. The switching parameters of the BS 200Nx are measured with the load connected. Additionally, the CA BS 200N includes a number of shunt resistors Rs such as 10ohm, 20ohm, 40ohm and 120ohm being required as per standards used during the emission measurement of transients as per ISO 7637-2:2011 and the former ISO 7637-2:2004.

Max battery supply voltage
28Vdc
Load current
Max. 50A
Operating time
13.5V supply approx. 1 hour
28.0V supply approx. 10 minutes
Overheat indication
LED
Protection
Switch Off (overtemperature sensor)
Cooling
Forced Air
Load
0.6ohm in series with 50uH
Parallel load resistor
10, 20, 40 or 120ohm, selectable via short circuit connectors
Dimensions
19 Inches /3HU, 133mm x 500mm x 500mm
Weight
19.1kg
Mains supply
80V to 240Vac
Fuse
1A slow blow