Description
Overview
This system by Teseq includes the NSG 3060 for EFT to 4.8kV, Surge to 6.6kV, 100 kHz Ringwave to 6.6kV with a three phase EFT & Surge CDN (480v/32amps). This is the combination of both the CDN 3063 and NSG 3060 which are priced and often rented desperately. This product is designed primarily for cable-borne transient interference tests. Both the pulse generator and the coupling/decoupling network come with an ISO 17025 accredited calibration.This is a combination of the NSG 3060 and CDN 3063, which can be rented as a complete system, or individually.
This Immunity Testing System was created for maximum reliability in a wide range of test setups. Over temperature protection, which allows short term operation at currents exceeding the nominal rating, prevents damage to internal components. The combination of both the NSG 3060 and CDN 3063 takes into account EUT power voltage levels allowing for testing to ANSI C62.41 and many others.
Data Sheet - NSG 3060Data Sheet - CDN 3063 Application Guide - CDNsSpecifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-12, ANSI C62.41, ANSI C62.45, & UL 1449 |
EFT Burst 5/50ns: |
|
Standards |
IEC 61000-4-4, ed.3 |
Voltage Waveform into 50Ω load |
5ns Rise Time±30%, 50ns pulse width ±30%, |
Voltage Waveform into 1000Ω load |
5ns Rise Time±30%, 50ns pulse width ±30%, |
Voltage Amplitude |
±100V – 2.4kV into 50Ω, ± 200V – 4.8kV into 1000Ω |
Burst Duration |
1µ to 1999 s |
Burst Period |
1 ms to 4200 s |
Frequency |
100Hz to 1000kHz |
Combination Wave Surge: |
|
Standards |
IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45 |
Open Circuit Voltage Waveform |
1.2µs Front Time ±30%, 50µs Duration ±20% |
Short Circuit Current Waveform |
8µ Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
200V–6.6kV |
Peak Short Circuit Current |
100A–3.3kA @2 Ω, 16.6-550A@12Ω |
100kHz Ringwave: |
|
Standards |
IEC 61000-4-12, EN 61000-4-12, ANSI C62.41.2 Cat A& B, ANSI C62.45 |
Open Circuit Voltage Waveform |
100kHz Damped Cosine, risetime=.5µs+/-30%, Damping= 40%/peak |
Peak Open Circuit Voltage |
200V–6.6kV @12 Ω or @ 30 Ω |
Peak Short Circuit Current |
±6.6 to ±220 A ±10%@30 Ω ±16.6 to ±550 A ±10%@12 Ω |
Impulse Repetition Rate |
10s from 200V to 4400V, 20s from 4401V to 6600V |
Dips and Interrupts: |
INA 6502 external variac is available as a separate option |
Common Standards |
EN IEC 61000-4-4, EN IEC 61000-4-5, EN 61000-4-12, ANSI C62.41, C62.45, UL 1449 |
External Three Phase CDN 3063: |
Other optional CDN’s (CDN 3063, 3083) are available also |
AC Voltage |
30-480 VAC, single or 3 phase |
AC Current |
32 A continuous, Max 50A for 10 min. |
DC Voltage |
0-125 VDC, 225 VDC if current <7A |
DC Current |
32 A continuous, Max 50A for 10 min |
Control |
Automatic through the NSG3060 |
Connection to generator |
Fischer S105 A 004/10.7 |
Weight |
42 kilograms, 100 pounds |
Dimensions |
45x31x56 cm, 18x12x22 inches |
Dips and Interrupts: |
INA 6502 external variac is available as a separate option |
All Accessories
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
NSG 3060 Full Accessory List
Item | Capabilities |
CDN 3061 | Single phase 270 V / 16 A automatic coupling decoupling network |
CDN 3063 |
Three phase 480 V / 32 A automatic coupling decoupling networks |
CDN 3083S-100 |
Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A |
CDN 3083B-100 | Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A |
Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet) |
|
CNV504N1.3 |
4kV coupler/decoupler for Surge & Ringwave on 4 data lines |
CDN 3425 |
Teseq Burst/EFT couple pulses to data lines. |
CM.CCL |
Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines |
CDN 3063-C32 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A |
CDN 3063-C63 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A |
CDN 8014/8015 |
Capacitive coupling clamp for burst |
CDN 163 |
Burst coupling network 100 A per phase (coupling all to ref ground) |
CDN 117/118 |
Coupling networks for signal-/data lines (surge) |
CAS 3025 |
Burst/EFT verification set |
MD 200A |
Voltage differential probe 7 kV |
MD 300 |
Current probe 5 kA |
INA 6501 |
Manual step transformer, 16 AAC, 0/40/70/80% |
INA 6502 |
Automatic step transformer, 16 AAC, 0/40/70/80% |
VAR 3005-S16 |
Automatic variable transformer, 1 x 16 A |
VAR 3005-D16 |
Automatic variable transformer, 2 x 16 A |
MFO 6501 |
Manual magnetic field option -4-8 |
MFO 6502 |
Automatic magnetic field option -4-8 |
INA 701 |
Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge* max. 1200 A/m -4-9 |
INA 702 |
Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 *) Pulse shape adapter INA 752 needed to surge generator |
INA 752 |
Pulse shape adapter |