EM Test LD 200N

Rent Load Dump Generator
In Stock - Order by 3 p.m. ships today
  • Generators Clipped Load Dump Pulses
  • Tests to ISO 7637-2 & ISO 16750-2 Load Dump
  • Built-in CDN Max 80 Volts 30 Amps
  • Pulse duration up to 1200 ms
  • Current ISO 17025 Accredited Calibration

Included Accessories

  • Load Dump Generator 
  • Power Cable
  • (4) Safety Lab Cables with Alligator Clips
  • Printed Manual
  • Calibration Documentation 
  • Software License
  • Software on USB Stick/Drive
  • (4) MC Connectors Sets
  • USB Cable
  • 9pin serial cable
  • Shipping Case
Can't find something? Contact Us
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description 

Load Dump pulses simulate a sudden battery disconnection (e.g. by corrosion) from the alternator. Cause the lost of the battery load the alternator generates an overvoltage impulse. Such Load Dump pulses are high energy pulses with a high potential of destruction.

The LD 200N simulates these high energy pulses having a duration time in the range of hundreds of milliseconds. The LD 200N generates the Load Dump pulses as per ISO 7637, ISO 16750-2, SAE J1113, SAE J1455, JASO and many more manufacturer specification, e.g. Ford, Chrysler, Renault, PSA, NISSAN etc. By means of a built-in clipping circuit the LD 200N also generates clipped load dump pulses as per international standards as well as manufacturer requirements.

Specifications:
Voltage
20V - 200 V +/- 10%
Built in Coupler
60V/30a
Options
Clipped Load Dump Waveform 5b
ISO 7637
Waveforms 5a and 7
Rise Time
5ms - 10ms (10-90%)
Pulse Duration
40-400ms (10-10%)
Internal Resistor
.5 ohm - 38 ohm, selectable in 0.1 ohm steps
Repetition Rage
Min. 30s
Freestyle Mode
Rise Time
10us - 10ms
Pulse Duration
10ms - 1.200 ms
Internal Resistor
Built in 0.5 - 38ohm , selectable in 0.1 ohm steps
Weight
25kg (55lbs)
Dimensions
500mm x 450mm x 290mm (19.68 x 17.71 x 11.41)
Video Guides
EM Test LD 200N Overview & Setup
Related Videos
LV124 Testing with the EM Test VDS 200Q100.2 & Autowave