Description
Conducted Immunity System Features
- 6.6kV Surge, Ring Wave, EFT, & 1-Phase CDN
- ISO 17025 Calibration All Components
- CDNs - 270 Voltage/ 16Amps 1-Phase EFT & Surge
- Free Technical Support & 2 Days Free Transit
- Touch Panel Screen, Easy to use Architecture
- Both IEC and ANSI coupling methods
- Turnkey Solution - Arrives Ready for Testing!
Overview
This system is the combination of the NSG 3060 with the CDN 3061 provides the pulse capabilities for electrical fast transients 4.8kV, surge/combination wave to 6.6kV, 100kHz ringwave to 6.6kV and offers solutions for both IEC, CE mark, & ANSI testing. The NSG 3060 can be rented individually or, as in this case, with a single phase coupler. It allows coupling EFT, surge, and ringwave up to 270V/16A. An ISO 17025 accredited calibration, technical support, and two days free transit time is included with the rental. A dips and interrupts transformer (INA 6502) is also available for rent for additional testing capabilities.
This Teseq system offers a user friendly design to help streamline testing to EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN 61000-4-12,ANSI C62.41, C62.45, and UL 1449. It offers a a 7" color screen and easy to manage user-interface allowing for easy adjustments with the thumb-wheel. Expansion capabilities enable the system to be configured for a much broader range of applications including 10/700 Telecom Surge and Magnetic Field tests. We also offer rentals of many accessories including the CDN 3083 series to facilitate additional testing capabilities.
The automated single-phase coupling network incorporates surge and burst coupling for continuous EUT currents of up to 16 A and complies to the requirements for the surge standard IEC/EN 61000-4-5, as well the coupling modes given in the ANSI C62.45 standard and for burst standard IEC/EN 61000-4-4.
Data Sheet - NSG 3060Data Sheet - CDN 3061 Application Guide - CDNsSpecifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, & EN 61000-4-12 ANSI C62.41, C62.45, UL 1449 |
External Single Phase CDN 3061: |
Other optional CDN’s (CDN 3063, 3083) are available also |
AC Voltage |
24 to 270 Vrms |
AC Current |
16 A, Max 25A for 30 min. |
DC Voltage |
0-270 VDC |
DC Current |
16 A, Max 25A for 30 min. |
EFT Burst 5/50ns: |
|
Standards |
IEC 61000-4-4, ed.3 |
Voltage Waveform into 50Ω load |
5ns Rise Time±30%, 50ns pulse width ±30%, |
Voltage Waveform into 1000Ω load |
5ns Rise Time±30%, 50ns pulse width ±30%, |
Voltage Amplitude |
±100V – 2.4kV into 50Ω, ± 200V – 4.8kV into 1000Ω |
Burst Duration |
1µ to 1999 s |
Burst Period |
1 ms to 4200 s |
Frequency |
100Hz to 1000kHz |
Combination Wave Surge: |
|
Standards |
IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45 |
Open Circuit Voltage Waveform |
1.2µs Front Time ±30%, 50µs Duration ±20% |
Short Circuit Current Waveform |
8µ Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
200V–6.6kV |
Peak Short Circuit Current |
100A–3.3kA @2 Ω, 16.6-550A@12Ω |
100kHz Ringwave: |
|
Standards |
IEC 61000-4-12, EN 61000-4-12, ANSI C62.41.2 Cat A& B, ANSI C62.45 |
Open Circuit Voltage Waveform |
100kHz Damped Cosine, risetime=.5µs+/-30%, Damping= 40%/peak |
Peak Open Circuit Voltage |
200V–6.6kV @12 Ω or @ 30 Ω |
Peak Short Circuit Current |
±6.6 to ±220 A ±10%@30 Ω ±16.6 to ±550 A ±10%@12 Ω |
Impulse Repetition Rate |
10s from 200V to 4400V, 20s from 4401V to 6600V |
Dips and Interrupts: |
INA 6502 external variac is available as a separate option |
Weight |
44 kilograms, 93 pounds |
Dimensions |
45x56x56 cm, 18x22x22 inches |
Packing List/Accessories
Included with Rental Of Teseq NSG 3060
Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping. We are also excited to offer many different testing accessories not standard with the immunity generator. A detailed list of these can be found on the "All Accessories" tab.
NSG 3060
- Conducted Immunity System
- Control Software USB with License
- Calibration Documentation
- Power Cord
- Laptop with Charger
- Cross Over/ Ethernet Cable
- Printed Manual
- Interlock/Keeper
- Black Plastic Screw
- WIN3000 Installation Guide
- Shipping Case
- Weight: 140 LBS
- Dimensions: 28x26x18
CDN 3061
- CDN 3061 #
- Power Cord
- EUT Power IN Cord
- EUT Power OUT Cord
- HV Burst SVH to SVH Cord
- 25 Pin System Cord - CDN to Generator
- (2) Surge Fischer/Fischer Cords
- Ground Strap
- Black Plastic Screw( attached to front)
- Calibration Documents
- EUT OUT Connector
- EUT IN Connector
- Shipping Case 28x26x18
All Accessories
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
NSG 3060 Full Accessory List
Item | Capabilities |
CDN 3061 | Single phase 270 V / 16 A automatic coupling decoupling network |
CDN 3063 |
Three phase 480 V / 32 A automatic coupling decoupling networks |
CDN 3083S-100 |
Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A |
CDN 3083B-100 | Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A |
Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet) |
|
CNV504N1.3 |
4kV coupler/decoupler for Surge & Ringwave on 4 data lines |
CDN 3425 |
Teseq Burst/EFT couple pulses to data lines. |
CM.CCL |
Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines |
CDN 3063-C32 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A |
CDN 3063-C63 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A |
CDN 8014/8015 |
Capacitive coupling clamp for burst |
CDN 163 |
Burst coupling network 100 A per phase (coupling all to ref ground) |
CDN 117/118 |
Coupling networks for signal-/data lines (surge) |
CAS 3025 |
Burst/EFT verification set |
MD 200A |
Voltage differential probe 7 kV |
MD 300 |
Current probe 5 kA |
INA 6501 |
Manual step transformer, 16 AAC, 0/40/70/80% |
INA 6502 |
Automatic step transformer, 16 AAC, 0/40/70/80% |
VAR 3005-S16 |
Automatic variable transformer, 1 x 16 A |
VAR 3005-D16 |
Automatic variable transformer, 2 x 16 A |
MFO 6501 |
Manual magnetic field option -4-8 |
MFO 6502 |
Automatic magnetic field option -4-8 |
INA 701 |
Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge* max. 1200 A/m -4-9 |
INA 702 |
Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 *) Pulse shape adapter INA 752 needed to surge generator |
INA 752 |
Pulse shape adapter |
Testimonials
I would recommend Transient Specialists. Transient Specialists always provides quality products within the established timeframes. The equipment always meets the specifications and properly shipped within the time frames within the time frames promised.
Scott D., TUV SUD Canada
Transient Specialists has been outstanding at working with us for our specialized EMC equipment rental needs. Fast shipments and excellent accommodation for some customized setups. I recommend them highly and they are a pleasure to partner with!
John H., Gates Air, Inc.
Laura, I want to thank you and Goran for your excellent customer service and turn around time on the rentals and the calibration documents.
Adam P., Clark Testing
Working for a testing company I deal with renting equipment all the time. Transient Specialist is the first company I call on my list of rental houses because of their great personnel, prompt delivery of the equipment, knowledgeable and accommodating to the customers needs.
Richard T., National Technical Systems